Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter transfer booster pump system testing for natural gas boosts pressure
Suncenter transfer booster pump system testing for natural gas boosts pressure

Suncenter transfer booster pump system testing for natural gas boosts pressure

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Application Scope
hydro test pump developed and produced by Suncenter Fluid Control Equipment is widely applied to many industries and fields. It can fully meet the diversified needs of customers.Suncenter Fluid Control Equipment always focuses on meeting customers' needs. We are dedicated to providing customers with comprehensive and quality solutions.
Product Comparison
Compared with products in the same category, hydro test pump has the following advantages.
Company Advantages
1. Suncenter co2 filling pump has been tested according to electrical regulations. It is tested in terms of radiated emissions, radiated susceptibility, ESD (electrostatic discharge), electrical transients, etc.
2. This product is known for its system reliability. It can perform the same task endlessly in the same way without loss.
3. The product features a rugged industrial-strength frame. It mainly adopts hot-rolled steel and wrought materials such as stainless steel materials for better resistance to impacts.
4. It promotes quality and tranquil sleep. This ability to obtain a sufficient amount of undisturbed sleep will have an immediate and long-term impact on a person's health.
5. There is a multitude of benefits when manufacturers use this product to upgrade production, such as increased productivity and lowered labor costs.

Air Driven Liquid CO2 Booster Pump-DGG/DGGD Series.


SUNCENTER pumps are air driven at a drive air pressure of 2bar to 8bar by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


Suncenter transfer booster pump system testing for natural gas boosts pressure-1



DGG Series Liquid CO2 Booster Pumps(Single acting)


Suncenter transfer booster pump system testing for natural gas boosts pressure-2
  • DGG Series Liquid CO2 Booster Pumps(Single acting)  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92

DGG130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14X1.5

1.47

DGG175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14X1.5

1.14


DGGD Series Liquid CO2 Pumps(Double acting)


Suncenter transfer booster pump system testing for natural gas boosts pressure-3
  • DGGD Series Liquid CO2 Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13

DGGD130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14*1.5

2.40

DGGD175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14*1.5

1.81


Suncenter transfer booster pump system testing for natural gas boosts pressure-4
  • Liquid carbon dioxide booster pump and pressurization equipment, commonly used in carbon dioxide supercritical extraction of various plant extracts, material foaming, and carbon dioxide fire extinguisher filling. Among them, carbon dioxide extraction is often used in biopharmaceuticals. Experimental research works by using a special pump for liquid carbon dioxide to pressurize carbon dioxide to a supercritical state, which is used to decompose various elements in plants for easy extraction.


DGGD series liquid CO2 pump working picture


Suncenter transfer booster pump system testing for natural gas boosts pressure-5
  • DGGD series liquid CO2 pump working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable for liquid CO2/liquid+gas mixed CO2/Supercritical CO2

  •   For liquid CO2 cylinder transfer/filling

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is a booster pump system production and management enterprise integrating industry and trade.
2. The increasing reputation of our booster pump price also contributes to the application of co2 filling pump technology.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd firmly believes excellence comes from long-term accumulation. Inquire! Constant improvements in quality and service is Dongguan Suncenter Fluid Control Equipment Co., Ltd's ultimate goal. Inquire! Suncenter strives to be a dominant liquid nitrogen pump manufacturer in the market. Inquire! We always place high quality of co2 pump in first place. Inquire!
For its material, we used co2 filling pump that was typical for co2 pump because it is co2 filling pump. This product stands out for its high sensitivity
booster pump price is made of high quality co2 pump with perfect performance such as co2 pump. This product has the ability to accurately convert a physical parameter into a signal
Our co2 filling pump are constantly updated to follow the trend. It is able to quickly and effectively detect and respond to some types of input
co2 pump is more applicable to liquid nitrogen pump with its features of liquid nitrogen pump. This product is mainly used for the automation process
co2 pump adopts co2 pump materials, generate features such as co2 pump. This product is mainly used for the automation process
The quality of the product has been greatly assured by out stringent process quality control system. This product has been certified under CE and RoHS
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting