Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  high reputation booster pump system transfer china for safety valve calibration
high reputation booster pump system transfer china for safety valve calibration

high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration
  • high reputation booster pump system transfer china for safety valve calibration

high reputation booster pump system transfer china for safety valve calibration

Suncenter N2O pump is composed of various electric components. It is constructed with heating components, PCB, power protector, automatic power-off protector, overpressure-low pressure protector, cable connector, etc. This product is very popular in many offices, clothes stores, printing shops, etc
latest_price_title
quantity_needed:
pieces
Courriel:

Air Driven Liquid CO2 Booster Pump-DGG/DGGD Series.


SUNCENTER pumps are air driven at a drive air pressure of 2bar to 8bar by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


high reputation booster pump system transfer china for safety valve calibration-1



DGG Series Liquid CO2 Booster Pumps(Single acting)


high reputation booster pump system transfer china for safety valve calibration-2
  • DGG Series Liquid CO2 Booster Pumps(Single acting)  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92

DGG130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14X1.5

1.47

DGG175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14X1.5

1.14


DGGD Series Liquid CO2 Pumps(Double acting)


high reputation booster pump system transfer china for safety valve calibration-3
  • DGGD Series Liquid CO2 Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13

DGGD130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14*1.5

2.40

DGGD175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14*1.5

1.81


high reputation booster pump system transfer china for safety valve calibration-4
  • Liquid carbon dioxide booster pump and pressurization equipment, commonly used in carbon dioxide supercritical extraction of various plant extracts, material foaming, and carbon dioxide fire extinguisher filling. Among them, carbon dioxide extraction is often used in biopharmaceuticals. Experimental research works by using a special pump for liquid carbon dioxide to pressurize carbon dioxide to a supercritical state, which is used to decompose various elements in plants for easy extraction.


DGGD series liquid CO2 pump working picture


high reputation booster pump system transfer china for safety valve calibration-5
  • DGGD series liquid CO2 pump working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable for liquid CO2/liquid+gas mixed CO2/Supercritical CO2

  •   For liquid CO2 cylinder transfer/filling

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





The development of Suncenter N2O pump is the soul of wit of our R&D team. It is developed with great performance and functionality by the R&D staff who have experience in energy conservation and consumption reduction, the knowledge of transformer and motor, and the wiring installation. The thermal printing method adopted in this product helps reduce printing cost because it needs no ink
Suncenter booster pump system is professionally designed. Its design is carried out by our designers who have improved the system components including geometric stress of the parts, the flatness of section, and connection mode. Without the capacity need for ribbons and ink, its design is more compact
Suncenter N2O pump is an up-to-date and practical design. It is designed in a simplistic style by the designers who are quite acquainted with market trends in the sanitary ware industry. Without the capacity need for ribbons and ink, its design is more compact
The manufacturing process of Suncenter N2O pump covers a series of steps. It goes through plastic pressing, insulation, resistance welding, and quality inspection & safety check. The drop-in paper loading is easy to handle
Suncenter N2O pump satisfies the general requirements for the safety of household and similar electrical appliances. It will be tested for safety issues including insulation, electric leakage, and short circuit. With an auto cutter, it simplifies the daily printing procedure
To assure its durability, the product has been tested for many times. It is less likely to occur the paper jamming problem
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting