Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter stable liquid nitrogen pump equipment for pressurization
Suncenter stable liquid nitrogen pump equipment for pressurization

Suncenter stable liquid nitrogen pump equipment for pressurization

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Company Advantages
1. The processing of Suncenter high pressure booster pump involves several basic steps: plasticizing, mixing, calendering or extrusion, forming, punching, cutting, vulcanizing and deflashing. The speed of this product is infinitely variable
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd keep well informed about liquid nitrogen pump technical developments, new application and new products in the field. It has flexibility without the use of unloaders or bypass valves
3. This product is very resistant to stains. In the production process, it was treated with soil release finishing agent to improve its ability to handle stains. This product has a compact and robust design
4. The product has good elongation. It has been tested under the stress-strain condition to check whether it will break with the increasing tensile load. The product has reliable performance and simple access to the operation
5. This product has good washability. During the material processing, the fabric has been cleaned by machine so that the fabric does not shrink again. This product can be installed at any predetermined pressure

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


Suncenter stable liquid nitrogen pump equipment for pressurization-1



DGG Series Liquid Gas Booster Pumps


Suncenter stable liquid nitrogen pump equipment for pressurization-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


Suncenter stable liquid nitrogen pump equipment for pressurization-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


Suncenter stable liquid nitrogen pump equipment for pressurization-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



Suncenter stable liquid nitrogen pump equipment for pressurization-5


The hottest selling- Model C cabinet picture


Suncenter stable liquid nitrogen pump equipment for pressurization-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. liquid nitrogen pump is assembled by our highly skilled professionals.
2. From improving management thought and strategy, Suncenter will always upgrade the job efficiency. Inquiry!
Suncenter high pressure booster pump is produced under a series of stringent procedures, including ultrasonic welding and soldering, electrode coating, cell assembly, in-house testing, and cell cycling and inspections. With superior clay mixed together,as well as through the fire in high temperature,the ceramic dinnerware sets are fire-resistance and safe
The steel construction of Suncenter high pressure booster pump is designed and engineered by our in-house professional engineers. The production of this steel- hot dipped galvanized- is also undertaken in-house by our experienced team. There are more than 30 different series of white ceramic dinnerware sets for hotel and restaurant use
Suncenter liquid nitrogen pump is produced under complete and complicated procedures conducted by professional technicians. These procedures include molding, applying on the pigment, low baking, and high-temperature sintering. The Two Eight restaurant crockery and cutlery sets with bright and smooth glaze are easy to clean
Suncenter high pressure booster pump meets the basic technical specifications for safety of textiles. It is produced under strict quality scrutinization by the QC team in terms of its material ingredients, agents, and processing techniques. Our ceramic dinner sets are suitable in many places like star hotels and restaurants, etc.Welcome to Two Eight factory to wholesale restaurant dishware sets
The surface treatment of Suncenter high pressure booster pump mainly includes degreasing, anodizing, sandblasting, painting, and laser engraving. It has to go through surface inspection to guarantee burr free. Fashion,high quality standards and diversification designs consistute of the white ceramic dinnerware sets
This product helps reduce the concentration of particulate matter such as suspended particles, bacteria, fungi parasites, viruses. We provide engineered 3D designs by 3D printer to meet your ideas
product_message
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting