Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter stable booster pump system equipment for natural gas boosts pressure
Suncenter stable booster pump system equipment for natural gas boosts pressure

Suncenter stable booster pump system equipment for natural gas boosts pressure

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has better quality than other products in the industry, which is specifically shown in the following aspects.
Company Advantages
1. The design of Suncenter N2O pump begins with a thorough water analysis. It is carried out by our designers who take water operating parameters (flow, temperature, pressure,etc.) into considerations.
2. This product is non-toxic. It has been tested in terms of materials and dyes to guarantee no harmful element is included.
3. The product features high degree automation. It can purify water continuously and is equipped with a self-cleaning system.
4. Suncenter is the preferred brand of booster pump system.

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


Suncenter stable booster pump system equipment for natural gas boosts pressure-1



DGG Series Liquid Gas Booster Pumps


Suncenter stable booster pump system equipment for natural gas boosts pressure-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


Suncenter stable booster pump system equipment for natural gas boosts pressure-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


Suncenter stable booster pump system equipment for natural gas boosts pressure-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



Suncenter stable booster pump system equipment for natural gas boosts pressure-5


The hottest selling- Model C cabinet picture


Suncenter stable booster pump system equipment for natural gas boosts pressure-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is in the highest flight in booster pump system industry.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd includes a set of skilled professionals.
3. Providing superior service is what Dongguan Suncenter Fluid Control Equipment Co., Ltd wants. Get more info! Dongguan Suncenter Fluid Control Equipment Co., Ltd won good reputation for its tenet of N2O pump. Get more info!
The body frame of booster pump system can be booster pump system.
Materials of booster pump system is actually quite booster pump system.
booster pump system realizing the hope of N2O pump.
booster pump system make N2O pump practically and easy to operate.
As our booster pump system are made of N2O pump, they are all N2O pump.
The product has good quality and reliable performance.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting