Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter energy saving co2 pump temperature for pressurization
Suncenter energy saving co2 pump temperature for pressurization

Suncenter energy saving co2 pump temperature for pressurization

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


Suncenter energy saving co2 pump temperature for pressurization-1



DGG Series Liquid Gas Booster Pumps


Suncenter energy saving co2 pump temperature for pressurization-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


Suncenter energy saving co2 pump temperature for pressurization-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


Suncenter energy saving co2 pump temperature for pressurization-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



Suncenter energy saving co2 pump temperature for pressurization-5


The hottest selling- Model C cabinet picture


Suncenter energy saving co2 pump temperature for pressurization-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Suncenter co2 transfer pump is delicately manufactured by the use of cutting edge technology. Robust construction, high tensile strength, easy installation, corrosion resistance, longer service life and high performance are some of the highlighting features of our offered range of products
Reliable raw materials: the raw materials of Suncenter co2 pump are all sourced from the suppliers who have established long term reliable cooperation with us. Their products are all certified. We manufacture and offer a wide range of CNC tenoning machine that has the capability to perform with high levels of consistency
Suncenter co2 pump is created a unique on a scientific and reasonable basis. These automatic double side planers are less power consuming which enable our clients to save money
During the manufacturing of Suncenter co2 pump, the source of raw materials is secured. These materials are purchased from some of the most top grade suppliers with good reputation. In order to ensure the long life and flawless performance, these high frequency wooden frame jointing machines are manufactured under the supervision of our team of experts using premium grade factor inputs and advanced technology in compliance with the set quality standards
Suncenter co2 pump is superior in raw materials: inferior raw materials are totally rejected into the factory. And the high quality raw materials are well accepted though they will increase the cost of production. Gewinn united is a well-known supplier and exporter of the technically superior Gewinn wood cutting machine which has been designed to perform the heavy duty
co2 transfer pump is geared to the needs of theco2 transfer pump, and is provided with peculiarity such as co2 transfer pump. Gewinn united is a well-known supplier and exporter of the technically superior Gewinn wood cutting machine which has been designed to perform the heavy duty
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting