Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  durable liquid nitrogen pump co2 supplier for pressurization
durable liquid nitrogen pump co2 supplier for pressurization

Durable liquid nitrogen pump co2 supplier for pressurization

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Product Comparison
Suncenter Fluid Control Equipment's booster pumps has been further improved based on advanced technology, as reflected in the following aspects.
Company Advantages
1. Suncenter liquid nitrogen pump is manufactured adopting advanced machines. These machines mainly include punching machine, bending machine, stamping machine, milling machine, cutting machine, etc.
2. It has amazing graphic and printing capabilities. It’s relatively easy to promote and create brand awareness using this product.
3. Most of our customers use it in the mechanical equipment to solve the medium leakage problems to save energy.

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


SUNCENTER pumps are air driven at a drive air pressure of 2 to 10bar (29 to145 psi) by the normal air compressor. Basically the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.


Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios.Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal outlet pressure can be calculated.


durable liquid nitrogen pump co2 supplier for pressurization-1



DGG Series Liquid Gas Booster Pumps


durable liquid nitrogen pump co2 supplier for pressurization-2
  • DGG Series Liquid Gas Booster Pumps  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92


DGGD Series Liquid Gas Pumps(Double acting)


durable liquid nitrogen pump co2 supplier for pressurization-3
  • DGGD Series Liquid Gas Pumps(Double acting) 


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

3-8 bar

4XPL

32

NPT1/2

NPT1/2

70.00

DGGD6

6:1

3-8 bar

6XPL

48

NPT1/2

NPT1/2

48.60

DGGD10

10:1

3-8 bar

10XPL

80

NPT1/2

NPT1/2

30.61

DGGD16

16:1

3-8 bar

16XPL

128

NPT1/2

NPT1/2

19.73

DGGD28

28:1

3-8 bar

28XPL

224

NPT1/2

NPT1/2

11.30

DGGD40

40:1

3-8 bar

40XPL

320

NPT1/2

NPT3/8

7.69

DGGD64

64:1

3-8 bar

64XPL

512

NPT1/2

NPT3/8

4.94

DGGD80

80:1

3-8 bar

80XPL

640

NPT1/2

NPT3/8

3.96

DGGD100

100:1

3-8 bar

100XPL

800

NPT1/2

NPT3/8

3.13



Suncenter DLS Series liquid gas filling booster pump system


SUNCENTER- Liquid gas filling pump systems are compact and delicacy solution tailored to customer specific requirements with air driven pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven pump have to be equipped with the air control unit combined filter, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


durable liquid nitrogen pump co2 supplier for pressurization-4


DLS liquid gas booster system = liquid gas booster pump+ following valves, gages, and parts



durable liquid nitrogen pump co2 supplier for pressurization-5


The hottest selling- Model C cabinet picture


durable liquid nitrogen pump co2 supplier for pressurization-6
  • The standard gas booster pumps system including following parts:

  • Air –driven liquid N2O/CO2/NOVEC/Refrigerant gas booster pump

  • Stainless steel (carbon steel) material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92


DLS-DGGD series Liquid gas booster system technical specification


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.00

DLS-DGGD6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

48.60

DLS-DGGD10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

30.61

DLS-DGGD16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DLS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30

DLS-DGGD40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

7.69

DLS-DGGD64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

4.94

DLS-DGGD80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

3.96

DLS-DGGD100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

3.13



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter booster pump will automatically start, keep the loop pressure constant

  •   Applicable for various kinds of gas such as N2O/CO2/NOVEC/Refrigerant etc.

  •   For liquid gas(liquid+gas mixture) cylinder transfer/filling/recovery

  •  For CO2 Fire Extinguisher filling 

  •   For Supercritical CO2 extraction


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd has been dedicated to the creation, production and sales of liquid nitrogen pump .
2. We employ a team of exceptional R&D talents with deep experience. They are engaged in the research and development of the products while keeping up with the market trend.
3. We attach great importance to sustainable development. We challenge our factories to adopt cleaner and more efficient operations to produce less waste and reduce our environmental footprint. We perform social responsibility in our business operation. One of our primary focus is the environment. We take steps to reduce carbon footprints, which is good for both the company and society. We value social responsibility. We achieve this through initiatives including active engagement in communities, being sustainable through people, plant, and performance, and so forth. We value sustainable development. We have instituted robust processes in measuring and monitoring our impact and we are making continual improvements.
Suncenter liquid nitrogen pump is professionally created under a strong design team who has excellent computer ability such as Autocad, Solidworks, CAD, and CAM. Established in 2014, Foshan Polyva materials CO., Ltd. specializes in development, manufacture and supply of water soluble PVA film
Suncenter high pressure booster pump is an exclusively designed thermal solution for particular applications. By enlarging its heat radiating area or optimizing the materials in the circulation parts is often conducted to check its heat dissipation performance. The adopted materials are all harmless which do no harm to human body
Suncenter high pressure booster pump is processed deeply with professional techniques, including drill hole, stretch bending, milling, welding, fabrication, as well as other chemical processes. The performance of our water-soluble PVA film for laundry detergent products has reached internationally advanced level
Advanced inspection measures are used in the production of Suncenter high pressure booster pump, such as coordinate measuring machine, gauges, roughness tester, and hardness tester. The adopted materials are all harmless which do no harm to human body
The quality of Suncenter high pressure booster pump is guaranteed to meet the standards of the heatsink industry, including the safety and electricity performance standards. Our products range covers cold water soluble packaging PVA film series which include over 10 different types
liquid nitrogen pump is applied to high pressure booster pump for its excellent properties of high pressure booster pump. Fast delivery can be guaranteed
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting