Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Accueil  >  Best PRODUCTS  >  Quality Gas Booster For sell  >  Quality Gas booster pump For sell  > 

Suncenter oxygen gas booster for safety valve calibration

Suncenter oxygen gas booster for safety valve calibration

Suncenter oxygen gas booster for safety valve calibration

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Product Details
With a focus on product quality, Suncenter Fluid Control Equipment pursues perfection in every detail.
  • Suncenter-gas booster ,nitrogen booster pump | Suncenter
Company Advantages
1. Various gas booster provided by Dongguan Suncenter Fluid Control Equipment Co., Ltd has reasonable structure and reliable quality.
2. This product has superior quality making them compatible and versatile for the industry.
3. The quality control is highlighted during production, ensuring the stable quality of the product.
4. Its domestic market appeal has gradually increased recent years.

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model



DGA series gas booster pumps(Single acting, single air drive head):  


Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-1
  • DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas Inlet pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  PL

Formula to
 calculate gas outlet pressure PB

Connection: Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

GA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGA60

60:1

20 

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


DGD series gas booster pumps(Double acting ):


Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-2
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection: Gas Inlet / Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-3
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.

  • DGT pumps are available with high quality seals, which provide significantly better service life

  • All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet 

pressure PA (bar)

Max.gas Inlet 

pressure PA (bar)

Max. gas outlet 

pressure PB (bar)

 Driven air pressure  

PL

Formula to calculate gas outlet pressure PB

Connection: Gas Inlet /
     Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )



Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-4
  • DGT series gas booster working picture 


Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-5


         Gas pressure booster for cylinder transfer and filling
Suncenter-High-quality Gas Booster | Gas Booster Dga60 Model-6


         DGS series gas booster system working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)  

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •    Pressures to 80Mpa (11,600 psi)

  •    Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd has grown into one of the very professional gas booster manufacturers.
2. nitrogen booster pump plays an important role in the quality assurance of oxygen pumps .
3. Suncenter thinks that a higher degree of customer satisfication needs professional service from experienced service team. Get price! Suncenter intends to progress in exporting pump booster . Get price!
Taux Favorable
100%
L'acheteur impression
Ce produit a pas d'acheteur impression
  • Tous les commentaires(0)
  • Louange (0)
  • Moyenne (0)
  • Mauvaise critique (0)
Message du produit
社媒暂无评论
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting