Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter highest fire extinguisher refill factory price for fire extinguisher
Suncenter highest fire extinguisher refill factory price for fire extinguisher

Suncenter highest fire extinguisher refill factory price for fire extinguisher

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Enterprise Strength
  • Suncenter Fluid Control Equipment insists on the principle to be honest, practical, and efficient. We continue to accumulate experience and improve service quality, so as to win praise from customers.
Product Comparison
hydro test pump's outstanding advantages are as follows.
Company Advantages
1. fire extinguisher refilling machine under Suncenter is obviously more aesthetically appealing than other brands.
2. Being a quality centric firm well-known in the market, the quality of our product is fully guaranteed.
3. fire extinguisher refill has stable quality and superior performance.
4. The product is increasingly accepted by customers in the industry.

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter highest fire extinguisher refill factory price for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter highest fire extinguisher refill factory price for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter highest fire extinguisher refill factory price for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter highest fire extinguisher refill factory price for fire extinguisher-4
Suncenter highest fire extinguisher refill factory price for fire extinguisher-5


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd has attracted many customers due to its first-class technology, high quality and competitive price.
2. We have a highly responsible QC team. They work and treat the quality control in a series manner to make sure every single product is 100% qualified prior to shipping.
3. Under the guidance of the enterprise management philosophy, Suncenter complied with the development trend of the times. Ask online! Suncenter regards fire extinguisher refilling machine as its core values to to enhance the development of the company. Ask online! Regardless of design or product, Dongguan Suncenter Fluid Control Equipment Co., Ltd always adheres to the core concept of 'innovation'. Ask online! Dongguan Suncenter Fluid Control Equipment Co., Ltd always regards product R&D and technological innovation as the internal driving force. Ask online!
Advantages

 

Related Products

 

Suncenter fire extinguisher refilling machine comes in a wide range of practical and creative designs. APTEK manufactures connectors up to the IEC international standard
By using advanced technology in the production, Suncenter fire extinguisher refilling machine has a delicate surface finish. APTEK makes sure that each connector matches different environmental standards in all countries
Suncenter fire extinguisher refill is designed by designers with the expertise of industry. APTEK produces connectors with precision, quality, and competitiveness
The whole production of Suncenter fire extinguisher refilling machine is under high-efficiency environment. APTEK has guaranteed the applications of connectors in food & beverage, chemicals, wood, LED lighting, etc
For being manufactured by using the state-of-the-art technology, Suncenter fire extinguisher refilling machine represents the high level of craftsmanship. Efficient response to all instructions from customers is a mission of APTEK
The vigorous development of fire extinguisher refilling machine due to its fire extinguisher refill features. APTEK produces connectors with precision, quality, and competitiveness
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting