Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter fire extinguisher refill for fire extinguisher
Suncenter fire extinguisher refill for fire extinguisher

Suncenter fire extinguisher refill for fire extinguisher

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Company Advantages
1. Suncenter fire extinguisher refill is the outcome of thermodynamics knowledge. Its whole body part especially the air circulation parts are made with special materials and circulating layout. The product can be mounted in any position
2. This product is very popular in the market and is widely used in the market. The product has reliable performance and simple access to the operation
3. This product has not only insulating, moisture absorbing and temperature compensating effects, but also the ability to adapt to body temperature. It has the capability of ultimate pressure, flow output horsepower
4. This product is anti-wrinkle. The twist of the yarn is professionally treated to an appropriate level to enhance the stretchability and elasticity of the yarn. The speed of this product is infinitely variable
5. The product has reliable working performance. It is able to withstand impact and high loading working conditions without sacrificing its efficiency. The speed of this product can be adjusted steplessly

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter fire extinguisher refill for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter fire extinguisher refill for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter fire extinguisher refill for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter fire extinguisher refill for fire extinguisher-4
Suncenter fire extinguisher refill for fire extinguisher-5


video





Company Features
1. Having been applying ourselves into the production of fire extinguisher refill, Suncenter aims to be the leading manufacturer. The R&D team in Dongguan Suncenter Fluid Control Equipment Co., Ltd is professional and experienced.
2. The fire extinguisher refill station is made by fire extinguisher filling equipment technology.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd has the advanced equipment and technology needed for automatic filling machine . Suncenter always holds onto the aim of being a fire extinguisher refill manufacturer. Please contact.
The design of Suncenter fire extinguisher filling equipment is thoughtful, accurate, and delicate, combining aesthetic look and functionality. It has a robust design, supported by an aluminum plate
The production of Suncenter fire extinguisher refill is adjusted to meet the needs of customers. It has a robust design, supported by an aluminum plate
Through the participation of technical staff, Suncenter fire extinguisher filling equipment has ranked top in its design. The dimension of this product can be customized according to needs
Suncenter fire extinguisher refill station is produced in fast and accurate flexibility of production methods. The operation of this product is controlled by microcomputer
Thanks to its design, Suncenter fire extinguisher filling equipment brings much convenience for customers. Equipped with a safety system, the product can detect the faults
The product is efficient in solar light absorption. The powder-coated exterior of the product allows it to absorb nearly all of the solar spectrum. The product generates little noise during operation
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting