Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher
Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher

Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-4
Suncenter cylinder fire extinguisher refill station bulk production for fire extinguisher-5


video





Suncenter fire extinguisher filling equipment is made of clay and other inorganic nonmetallic minerals which are guaranteed to be free of lead, cadmium, and other heavy metal elements. Featuring automatic thermal cut-off function, the product will not accumulate too much heat
The raw materials of Suncenter fire extinguisher refill station are finely processed in a ball grinding mill to triturate to more fine and smooth powder to make sure high-quality and exquisite product. The product is very popular in Europe, North America, Korea, and Japan
Suncenter fire extinguisher refill station has achieved quality management system certification in accordance with both domestic and international standards in regards to porcelain manufacture. The product can withstand a wide range of operating temperature from -29ºC to +45.5ºC
Regarding the appearance treatment, Suncenter fire extinguisher refill station meets the domestic quality standards for porcelain. There are no more than two flaws including glaze peels, crack, dark spot, and bubble. The product has passed the global certifications such as safety standard: IEC/EN61558
From the selection of raw material of Suncenter fire extinguisher filling equipment to burnishing, body repairing, glazing, and sintering, quality management is conducted throughout every stage. The strong housing helps protect against scratches, bumps, and drops
Core key words] It is made of high-quality raw materials fired at high temperature, with low water absorption, good thermal stability, lead-free and cadmium-free, safe and reliable quality, you can buy and use with confidence.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting