Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter test pressure booster pump from manufacturer for safety valve calibration
Suncenter test pressure booster pump from manufacturer for safety valve calibration

Suncenter test pressure booster pump from manufacturer for safety valve calibration

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Company Advantages
1. Suncenter pressure booster pump has a stylish and exclusive look at an affordable price. Its special design can effectively eliminate the dangers
2. This product can be used effectively for various application purposes. Its seal systems are designed for a long working life
3. The implementation of the quality control system ensures that the product is defect free. Its output pressure can be easily adjustable

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter test pressure booster pump from manufacturer for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


Suncenter test pressure booster pump from manufacturer for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter test pressure booster pump from manufacturer for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. Years of factory experience in manufacturing pressure booster pump makes Dongguan Suncenter Fluid Control Equipment Co., Ltd outstanding in its industry. Suncenter has excellent technology and guarantees the quality of nitrogen pumps.
2. Now the capital technology of Dongguan Suncenter Fluid Control Equipment Co., Ltd is abundant.
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd is highly recommended for the technology to help ensure the quality of hydraulic test bench . Dongguan Suncenter Fluid Control Equipment Co., Ltd will make unremitting efforts to build a world-class gas booster compressor enterprise group. Ask online!
The production of Suncenter gas booster compressor is of a high standard. It meets the building industry's critical standards and regulations such as the latest safety science and environmental protection certifications. APTEK could provide customers with safe, reliable, and easy-installed connectors
Suncenter hydraulic test bench has to go through five basic production processes: raw material extraction, compounds mixture, forming, cutting, and final surface treatment. APTEK, founded in 2009, focuses on developing connectors & sensors
In the manufacture of Suncenter gas booster compressor, a range of techniques have been used, from CAD design, 3D imaging, model manufacturing, to final assembly. APTEK, founded in 2009, focuses on developing connectors & sensors
The production of Suncenter gas booster compressor includes overall three parts: the production of filament, the bulb, and the base, which is highly automated. APTEK manufactures connectors up to the IEC international standard
The law of heat conduction theory has been adopted in the developing of Suncenter pressure booster pump. It's specially made to allow the heat to be transferred from the higher temperature region to the lower temperature region. APTEK has guaranteed the applications of connectors in food & beverage, chemicals, wood, LED lighting, etc
The product is reliable with consistent performance. At APTEK, certificates such as ROHS and UL are strong evidence of our capabilities
Message du produit
Chat en ligne 编辑模式下无法使用