Devenez le premier expert mondial en contrôle des fluides haute pression.

Suncenter  >  AI - Page Sitemap  >  Suncenter refrigerant refrigerant pump export for refrigeration industry
Suncenter refrigerant refrigerant pump export for refrigeration industry

Suncenter refrigerant refrigerant pump export for refrigeration industry

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Air driven refrigerant booster pump-SLM06


It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1.


When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.


No refrigerant heating from the motor.


Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard.


Suncenter refrigerant refrigerant pump export for refrigeration industry-1
  • Air driven refrigerant booster pump-SLM06  


Driving air need

2-8bar

Pressure range

0-48bar

Pressure ratio

6:1

Flow rate

15L/min

Driving air size

ZG1/2

Increasing

63mm

Inlet size

ZG1/2

Stroke

60mm

Outlet size

ZG1/2

Noise

<75dB


DGS- SLM06 model refrigerant pump system


Suncenter refrigerant refrigerant pump export for refrigeration industry-2
  • The standard system including following parts:

  • SLM06 model refrigerant pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS- SLM06 system = SLM06 booster pump+ following valves, gages, and parts


Suncenter refrigerant refrigerant pump export for refrigeration industry-3


DGS- SLM06 model refrigerant pump system with 16L Accumulator


Suncenter refrigerant refrigerant pump export for refrigeration industry-4
  • DGS- SLM06 model refrigerant pump system with 16L Accumulator


DGS-SLM06 model refrigerant pumps working picture


Suncenter refrigerant refrigerant pump export for refrigeration industry-5
Suncenter refrigerant refrigerant pump export for refrigeration industry-6



features

It's such a device that uses compressed air as power source, air driven refrigerant pump as pressure source and refrigerant as working medium, to get the corresponding high pressure value through  regulating air drive pressure; and the ratio of output pressure to air drive pressure is 6:1. When air drive pressure and outlet pressure reach balance, the refrigerant pump will stop pressurizing, and output pressure will be stable at the preset pressure, so it has such features: explosion-proof, output pressure adjustable, small volume, light weight, easy to operate, reliable performance, wide application range etc.  


  •   Cool operation—No heat generated during liquid transfer. Minor warming during vapor transfer.

  •   No refrigerant heating from the motor. 

  •   Safety—Pneumatically driven. Operates from air hose like an air tool. No electrical hazard. 


video





The design of Suncenter refrigerant pump mainly focuses on people. It considers the relationship between wearer and safety, hygiene, comfort level, and beauty. The product is easy to maintain and helps improve productivity
The flow chart of Suncenter liquid refrigerant pump manufacturing is as followed: fit sample making, fabric cutting, cutting parts sorting or bundling, sewing, ironing, and laundering. This product features energy saving and environmental protection
The manufacturing process of Suncenter refrigerant pump includes the following stages: garment market trend research, construction design, sampling, pattern cutting, sewing, and workmanship assessment. Its special design can effectively eliminate the dangers
The fabrics of Suncenter refrigerant pump have gone through all the necessary finishing processes. These processes include bleaching, dyeing, printing, heat setting, etc. The speed of this product can be adjusted steplessly
Suncenter liquid refrigerant pump will be inspected to guarantee high quality. It will be scrutinized to eliminate the circumstances of skipping stitches, sparse needle pitch, loose thread, floating thread, and break stitches. The product is perfectly suitable for the most demanding industrial applications
This product has high quality and stable functionality. This product has the advantages of speed and efficiency
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting