Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter nitrogen pumps marketing for natural gas boosts pressure
Suncenter nitrogen pumps marketing for natural gas boosts pressure

Suncenter nitrogen pumps marketing for natural gas boosts pressure

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Application Scope
Suncenter Fluid Control Equipment's gas booster has a wide range of applications.With a focus on customers, Suncenter Fluid Control Equipment analyzes problems from the perspective of customers and provides comprehensive, professional and excellent solutions.
Company Advantages
1. The design of Suncenter nitrogen pumps sticks up with the current market trend.
2. The product is not likely to accumulate too much heat. Its powerful cooling system is designed to maintain the proper temperature of mechanical parts, allowing it to have good heat dissipation.
3. The product features an easy operation. It has a relatively simple operating system combining a powerful processing flow and provides simple operation instruction.
4. The product can brighten up immediately when powered on, which has great advantages for people who are in needs of lighting in case of an emergency.
5. People can take it anywhere for various purposes including propaganda, holding an opening ceremony, or commercial exhibition.

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter nitrogen pumps marketing for natural gas boosts pressure-1



DGA series gas booster pumps(Single acting, single air drive head):


Suncenter nitrogen pumps marketing for natural gas boosts pressure-2
  • DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas Inlet pressure PA (bar)

Max.gas Inlet pressure PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGA02

2:1

1.0

16

16

2bar-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGA05

5:1

0

40

40

2bar-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGA06

6:1

2.0

48

48

2bar-8 bar

6XPL

1/2 / 1/2

360(at PA of 10 bar )

DGA10

10:1

3.5

80

80

2bar-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

GA15

15:1

3.5

120

120

2bar-8 bar

15XPL

3/8/ 3/8

190(at PA of 10 bar )

DGA25

25:1

7.0

200

200

2bar-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGA40

40:1

10

320

320

2bar-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGA60

60:1

20

480

480

2bar-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGA100

100:1

25

800

800

2bar-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )


DGD series gas booster pumps(Double acting ):


Suncenter nitrogen pumps marketing for natural gas boosts pressure-3
  • DGD series pumps are double acting, with single air driven heads type.   

  • DGD pumps are available with high quality seals, which provide significantly better service life

  • Double pump heads with exhaust cooling devices. 

  • All components in contact with the gas are made of stainless steel. 

  • Pipes mounting way are available as customized.


Model

Pressure boost ratio

Min. gas
Inlet pressure
     PA (bar)

Max.gas
Inlet pressure
     PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGD10

10:1

3.5

80

80

2bar-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGD15

15:1

5

120

120

2bar-8 bar

15XPL+ PA

3/8/3/8

350 (at PA of 6 bar )

DGD25

25:1

10

200

200

2bar-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGD40

40:1

15

320

320

2bar-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGD60

60:1

25

480

480

2bar-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGD100

100:1

35

800

800

2bar-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

DGD130

130:1

50 

1040

1040 

2bar-8 bar

130XPL+ PA

1/4/M14*1.5

180(at PA of 60 bar )


2DGD series gas booster pumps(Double acting, double air driven heads ):


Suncenter nitrogen pumps marketing for natural gas boosts pressure-4
  • Gas booster pump with max 800 bar outlet pressure


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGD10

10:1

3

80

80

2bar-8 bar

10XPL+ PA

1/2 / 1/2

980(at PA of 6 bar )

2DGD25

25:1

6

200

200

2bar-8 bar

25XPL+ PA

3/8 / 3/8

560(at PA of 10 bar )

2DGD40

40:1

25

320

320

2bar-8 bar

40XPL+ PA

3/8 / 3/8

480(at PA of 40 bar )

2DGD60

60:1

30

480

480

2bar-8 bar

60XPL+ PA

3/8 / 3/8

320(at PA of 40 bar )


DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter nitrogen pumps marketing for natural gas boosts pressure-5
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure. 

  • DGT pumps are available with high quality seals, which provide significantly better service life 

  • All parts in contact with the gas are made of stainless steel.


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


Suncenter nitrogen pumps marketing for natural gas boosts pressure-6
  • Gas booster pump with max 800 bar outlet pressure 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System


Suncenter - Pneumatic gas booster system are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter nitrogen pumps marketing for natural gas boosts pressure-7


Suncenter nitrogen pumps marketing for natural gas boosts pressure-8


The hottest selling- model A and model C cabinet picture


Suncenter nitrogen pumps marketing for natural gas boosts pressure-9
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter nitrogen pumps marketing for natural gas boosts pressure-10
  • DGT series gas booster working picture 


Suncenter nitrogen pumps marketing for natural gas boosts pressure-11


         Gas pressure booster for cylinder transfer and filling
Suncenter nitrogen pumps marketing for natural gas boosts pressure-12


         DGS series gas booster system working picture



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio  

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. Dongguan Suncenter Fluid Control Equipment Co., Ltd is a technology-intensive enterprise specializing in the production and sales of nitrogen pumps.
2. Dongguan Suncenter Fluid Control Equipment Co., Ltd has strong R&D ability and the high quality control system.
3. The motto of our company is diligence, intelligence, determination, and perseverance. We continue to uphold this motto as the basis of our management ideology. Seeking international growth by going global is regarded as our goal. We are going to extend the sales life of existing products and services by finding new markets to sell them in, which will eventually contribute to our profit growth and increased market share. We have a clear target: to take the lead in the international markets. Besides providing customers excellent quality, we also pay attention to every customer's demands and strive hard to meet their needs.
The whole production of Suncenter nitrogen pumps is carried out by skillful, experienced professionals.
The design of nitrogen pumps is scientific and rational.
The design style of Suncenter nitrogen pumps keeps receiving a good market response.
Suncenter haskel gas booster is precisely manufactured using premium quality raw materials and advanced technology by our adroit professionals.
We maintain the highest level of product structure from the initial phase of Suncenter nitrogen pumps development.
This product has a high gain performance. Its special surface coating enhances color reproduction and black level contrast with wide uniformity.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting