Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter lpg booster gas for safety valve calibration
Suncenter lpg booster gas for safety valve calibration

Suncenter lpg booster gas for safety valve calibration

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Compressed Air Driven Liquid Gas Booster Pump-DGG/DGGD Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Suncenter lpg booster gas for safety valve calibration-1



DGGD4 model special gas booster pump


Suncenter lpg booster gas for safety valve calibration-2
  • Application: various kinds of liquefying gas such as LNG, LPG, butane, propane, DME, etc  


Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min)**

DGGD4

4:1

2bar-8 bar

4XPL

8bar-32bar

NPT1/2

NPT1/2

70.00


DGGD4 model LPG pump for cylinder transfer working picture


Suncenter lpg booster gas for safety valve calibration-3
  • DGGD4 model LPG pump for cylinder transfer working picture 



We could also make it into a booster pump station:DGS-DGGD4


Suncenter lpg booster gas for safety valve calibration-4
  • The standard system including following parts:

  • DGGD4 model gas booster pump

  • Stainless steel frame cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


DGS-DGGD4 =Suncenter booster pump(DGGD4)+following valves, gages, and parts


Suncenter lpg booster gas for safety valve calibration-5



features

  •  Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar 

  •   No airline lubricator required 

  •   Hydrocarbon free - separation between air and gas sections 

  •   Pressures to 80Mpa (11,600 psi)   

  •   Wide range of models with different ratios 

  •   Built-in-cooling on most models 

  •   Easy to install, operate and maintain 

  •   Best price / performance ratio 

  •   No heat, flame or spark risk and explosion proof 

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant not be higher than 8 bar


video





Suncenter booster gas production conforms to international manufacturing standards. Therefore, the use of toxic bleaching agents, dyes and other chemicals is limited. We provide one stop service of Design-Prototype-Injection mould
The mechanical parts of Suncenter lpg pump price require precision machining. They have to go through deburring, polishing, milling, drilling, threading, grinding, turning, etc. Prototype is made by CNC Milling,and the involved surface finishing including polishing, painting, the logo sticking
The workmanship of Suncenter booster gas is of high quality. The product has passed quality inspection and testing in terms of joint connecting quality, crevice, fastness, and flatness that are required to meet a high level in upholstery items. The simulation of our products is good
In the design stage of Suncenter booster gas, many factors have been taken into account. These considerations include fire resistance ability, safety hazards, structural comfort & stability, and the content of contaminants and harmful substances. With its own superb technology and efficient service, Tuowei hand model is well accepted at home and abroad
Suncenter [拓展关键词 goes through a series of assessments. They are the taste and style preferences of consumers, decorative function, colorfastness, aesthetics, and durability. With its own superb technology and efficient service, Tuowei hand model is well accepted at home and abroad
lpg pump price Reasonable design, compact structure, excellent workmanship, reliable quality, simple installation, convenient use, anti-corrosion, wear-resistant, shock-resistant, drop-resistant, waterproof and dust-proof, etc., is a reliable high-quality scanner product.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting