Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter long life hydrostatic test pump producer forshipbuilding
Suncenter long life hydrostatic test pump producer forshipbuilding

Suncenter long life hydrostatic test pump producer forshipbuilding

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Suncenter DLS Series hydraulic pressure test pump


SUNCENTER- Hydraulic test benches are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa.


As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.


The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure. 


Suncenter long life hydrostatic test pump producer forshipbuilding-1


Suncenter long life hydrostatic test pump producer forshipbuilding-2



DLS Sereis hydraulic pressure test bench-The hottest selling Model C cabinet


Suncenter long life hydrostatic test pump producer forshipbuilding-3
  • The standard hydraulic test bench including following parts:

  • Air –driven liquid booster pump

  • Stainless steel material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge, water tank

  • Liquid inlet/outlet switch, high pressure liquid guage, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter long life hydrostatic test pump producer forshipbuilding-4
Suncenter long life hydrostatic test pump producer forshipbuilding-5


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet    port

High pressure Outlet port

MAX Flow
     (L/min)**

DLS-DGGD4

4:1

3-8 bar

4XPL

32

G 1/2

NPT/ZG

70.0

DLS-DGG6

6:1

3-8 bar

6XPL

48

G 1/2

NPT/ZG

29.91

DLS-DGG10

10:1

3-8 bar

10XPL

80

G 1/2

NPT/ZG

18.84

DLS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DLS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DLS-DGG40

40:1

3-8 bar

40XPL

320

G 1/2

NPT/ZG

4.89

DLS-DGG64

64:1

3-8 bar

64XPL

512

G 1/2

NPT/ZG

3.08

DLS-DGG80

80:1

3-8 bar

80XPL

640

G 1/2

NPT/ZG

2.44

DLS-DGG100

100:1

3-8 bar

100XPL

800

G 1/2

NPT/ZG

1.92

DLS-DGG130

130:1

3-8 bar

130XPL

1040

G 1/2

NPT/ZG

1.47

DLS-DGG175

175:1

3-8 bar

175XPL

1400

G 1/2

NPT/ZG

1.14

DLS-DGG255

255:1

3-8 bar

255XPL

2040

G 1/2

NPT/ZG

0.75

DLS-DGG400

400:1

3-8 bar

400XPL

3200

G 1/2

NPT/ZG

0.48

DLS-DGG510

510:1

3-8 bar

510XPL

4080

G 1/2

NPT/ZG

0.65

DLS-DGG800

800:1

3-8 bar

800XPL

6400

G 1/2

NPT/ZG

0.42


video





Suncenter hydraulic pressure test pump has passed the test for flammability. The testing principle is straightforward. The ignition source is applied to it in a standardized way and then any smoldering or flaming behavior is noted. It takes less time in assembling a circuit as compared to the conventional method
Suncenter hydrostatic test pump has passed through various performance tests, including high voltage test (dielectric withstand test), leakage current test, and ground continuity test. Its assembly process is conducted by a computer, leaving very little room for error
The materials used to make Suncenter hydrostatic test pump are toxic free and safe for users and the environment. They are tested for low emission (low VOCs). It offers a simple platform to arrange the electronic components in a compressed way
Suncenter hydrostatic test pump is produced based on various theories. It adopts the heat management theory to check and make sure the optimized working temperature for the battery cells. It improves the wiring density and reduces the spacing of components
Suncenter hydrostatic test pump is of flexible design. It is created by our designers who understand elements of design and use them in different ways to produce different kinds of art/objects and visual effects. Its simple design makes it easier for users to maintain and manipulate
This product is long-lasting. It has been optimized to prevent any leak and the electrolyte are made with a precise formula for pre-aging. It plays an important role in modern electronic equipment
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting