Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  Suncenter gas nitrogen pumps order now for natural gas boosts pressure
Suncenter gas nitrogen pumps order now for natural gas boosts pressure

Suncenter gas nitrogen pumps order now for natural gas boosts pressure

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Enterprise Strength
  • Suncenter Fluid Control Equipment adheres to the service purpose to be attentive, accurate, efficient and decisive. We are responsible for every customer and are committed to providing timely, efficient, professional and one-stop services.
Company Advantages
1. Suncenter gas booster system is carefully designed with insulation materials to prevent fire hazards due to excessive temperature or even melting.
2. The product is of the highest quality, performance and durability.
3. The service life of this product is highly guaranteed by the strict test procedure which is in line with international standard. It is tested to be high performance and user-friendly.
4. One benefit is that there are so many accessories that one can have with this product such as container padlocks and container lockboxes (which add additional security), container lighting, container ramps, moisture traps, etc.

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter gas nitrogen pumps order now for natural gas boosts pressure-1



The hottest selling- Model C frame type cabinet picture


Suncenter gas nitrogen pumps order now for natural gas boosts pressure-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter gas nitrogen pumps order now for natural gas boosts pressure-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Company Features
1. The capacity for nitrogen pumps is big enough to supply many customers at same time.
2. Together with the growth of society, Suncenter has been emphasizing the importance of top quality of gas booster compressor .
3. To maintain our commitment to environmentally sustainable development, we will step up our speed and put more effort into lessening our carbon footprint and pollution. Our company bears social responsibilities. Depending on the type of waste, we make a detailed recycling strategy to manage the waste effectively, enabling us to minimize the amount of waste sent to the landfills, protect the diminishing resources, and minimize hazardous waste. Our company bears social responsibility. We assess ourselves annually from four sustainability dimensions: environment, labor practices, fair business practices, and sustainable procurement. And we make efforts to do better. We are committed to continuously improve in all aspects of our operations, including our internal and external standards for excellent customer service.
Suncenter gas booster compressor has passed the following test. It has been tested in terms of statics, dynamics, material strength, vibration, reliability, fatigue, etc. It has passed AOI which ensures there will be no errors or welding defects
Suncenter gas booster compressor is professionally designed. Its design includes material design, system design, mechanical design and component structure design. It is characterized by high thermal conductivity and good heat dissipation
The workpiece of Suncenter gas booster system will be fabricated in a professional manner. Their dimensional stability and mechanical properties will be guaranteed with high quality after cold and heat treatment. With a compact design, it is space-saving
The development of Suncenter nitrogen pumps uses many disciplines. They include numerical control technology, dynamic machinery, mechanical engineering and technology, tribology, thermodynamics, etc. With a compact design, it is space-saving
The manufacture of Suncenter gas booster system is exquisite. Its components and parts have been sophisticatedly fabricated by abrasive machining, CNC machining, drilling, honing, etc. Its solderable surface is protected from the oxidation
The product is durable enough. Its main body is made of premium and high performance fiberglass materials and sturdy steel. Being laminated by advanced vacuum lamination equipment, it has a uniform dielectric thickness after lamination
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting