Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter dgt nitrogen pumps type for natural gas boosts pressure
Suncenter dgt nitrogen pumps type for natural gas boosts pressure

Suncenter dgt nitrogen pumps type for natural gas boosts pressure

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


Suncenter dgt nitrogen pumps type for natural gas boosts pressure-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


Suncenter dgt nitrogen pumps type for natural gas boosts pressure-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


Suncenter dgt nitrogen pumps type for natural gas boosts pressure-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Suncenter automatic booster pump is scientifically designed. Correct mechanical, hydraulic, thermodynamic and other principles are applied while designing its elements and the whole machine.
Suncenter nitrogen pumps is engineered with the assistance of computers and various software. They are Computer-Aided Manufacturing (CAM) which includes CNC tool path and rapid prototyping as well as Engineering analysis and simulation which include finite element, fluid flow, dynamic analysis, and motion.
Material is also a key factor in determining the final machine performance of Suncenter automatic booster pump. Therefore, all of the materials and components have to be tested for mechanical properties.
Practicality and aesthetic values are all considered in the design of Suncenter automatic booster pump, such as modeling elements, the law of color mix, and spatial processing.
Suncenter nitrogen pumps is exquisitely designed. It is the result of a wide range of technical expertise in building systems, materials and computer equipment, as well as models.
automatic booster pump Manufactured by advanced manufacturing technology and craftsmanship, with fast response, stable information transmission and strong recognition ability, it is a functional and practical scanner product.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting