Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration
Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration

Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


Suncenter booster hydrostatic pressure test from manufacturer for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Suncenter pneumatic test bench is manufactured with the support of expert professional. The cooling system installed enables it to bring lower heat
We develop Suncenter pneumatic test bench using hi-tech tools and equipment. It can be delivered fast thanks to our location in Shenzhen which enjoys traffic convenience
The direction pneumatic test bench will develop towards is to meet your requirements. The product is marketed with an independent intellectual property right
Suncenter hydrostatic pressure test is made of safe materials to ensure safe use. The imported production equipment is run to guarantee accuracy and quality
All design styles of Suncenter pneumatic test bench are fit for customer needs. It has several colors such as black and silver for options
The product meets international quality standards and can withstand any rigorous quality and performance testing. It is marketed under our own brand namely Ambition Mods which will soon be a leader in this field
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting