Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  newly fire extinguisher refill station co2 at discount for fire extinguisher
newly fire extinguisher refill station co2 at discount for fire extinguisher

newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher
  • newly fire extinguisher refill station co2 at discount for fire extinguisher

newly fire extinguisher refill station co2 at discount for fire extinguisher

Suncenter fire extinguisher refill station goes through a complete design cycle. It includes drawing up specifications, conception&architecture of the mechanism, design and simulation of behavior with static, dynamic, thermal, etc. The product is equipped with air conveyor and frequency control
latest_price_title
quantity_needed:
pieces
Courriel:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


newly fire extinguisher refill station co2 at discount for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


newly fire extinguisher refill station co2 at discount for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


newly fire extinguisher refill station co2 at discount for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


newly fire extinguisher refill station co2 at discount for fire extinguisher-4
newly fire extinguisher refill station co2 at discount for fire extinguisher-5


video





Suncenter fire extinguisher filling equipment has gone through a complete design process. It has been designed in terms of mechanical structure, spindles, and drive system, control, and inspection systems, etc. The product is widely used for commercial applications
The development of Suncenter fire extinguisher filling equipment has taken different factors into consideration. They are mainly structure fabrication, mechanical parts stability, welding quality, and the whole machine efficiency. Made of stainless steel materials, the product has a smooth surface to resist dust and dirt
Suncenter fire extinguisher refill station has been designed by considering many critical factors. They include statics, dynamics, thermal performance, support points, yield points, etc. Made of stainless steel materials, the product has a smooth surface to resist dust and dirt
The components or materials of Suncenter fire extinguisher refill station are sourced according to strict requirements. For example, its mechanical components such as motor and engine are selected and sourced from qualified suppliers who will be rigorously assessed. It can be configured in a straight line or in an L-shaped configuration
Suncenter fire extinguisher filling equipment is manufactured with the integration of various aspects. It is built with an energy flow system (EFC), information flow system, mechanical structure system, and mechanical motion system. It can be configured in a straight line or in an L-shaped configuration
The product is not likely to accumulate too much heat. Its powerful cooling system is designed to maintain the proper temperature of mechanical parts, allowing it to have good heat dissipation. The use of this product helps in increasing the production of drinks
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting