DGS-FM-5A model automatic FM200 filling machineSolution A (DGS-FM-5A) added the sensors, electromagnetic valve...
latest_price_title
quantity_needed:
pieces
Courriel:

DGS-FM-5A model automatic FM200 filling machine


Solution A (DGS-FM-5A) added the sensors, electromagnetic valve, vacuum pump, and the electronic scale based on solution B (manual control),it is automatic control mode


newly fire extinguisher refill machine for fire extinguisher-1
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: FM200/ NOVEC/Nitrogen

  • Boost ratio: 5:1

  • Output pressure: 4.2 Mpa/5.3Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Nitrogen/FM200 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread

  • Electric scale range:0-500kg(there is also max 1000kg for optional)


DGS-DGGD16 model liquid CO2 filling equipment


newly fire extinguisher refill machine for fire extinguisher-2
  • The CO2 Fire Extinguisher filling equipment including following parts:

  • Air–driven liquid CO2 gas booster pump

  • Stainless steel material cabinet

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’special requirement.


Model

Pressure Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet
     Pressure(bar)*

Driven
     air inlet port

High pressure Outlet port

MAX Flow
     (L/min)**

DGS-DGG16

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

12.42

DGS-DGG28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

7.11

DGS-DGGD166

16:1

3-8 bar

16XPL

128

G 1/2

NPT/ZG

19.73

DGS-DGGD28

28:1

3-8 bar

28XPL

224

G 1/2

NPT/ZG

11.30


DGS-CO2-B model liquid CO2(fire extinguisher) filling machine


newly fire extinguisher refill machine for fire extinguisher-3
  • Main parameters:

  • The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

  • Medium: CO2

  • Max output pressure: 12.8Mpa

  • Driven air inlet port: fast insert 12 per cent

  • Liquid CO2 inlet port: ZG3/8 internal thread

  • High pressure gas outlet port: ZG3/8 internal thread


Fire Extinguisher filling


newly fire extinguisher refill machine for fire extinguisher-4
newly fire extinguisher refill machine for fire extinguisher-5


video





Suncenter fire extinguisher filling equipment production conforms to international manufacturing standards. Therefore, the use of toxic bleaching agents, dyes and other chemicals is limited. The surface of our prototypes is smooth and flat
The mechanical parts of Suncenter fire extinguisher refill require precision machining. They have to go through deburring, polishing, milling, drilling, threading, grinding, turning, etc. PMMA material makes plastic products clear and transparent
The workmanship of Suncenter fire extinguisher refill is of high quality. The product has passed quality inspection and testing in terms of joint connecting quality, crevice, fastness, and flatness that are required to meet a high level in upholstery items.
In the design stage of Suncenter fire extinguisher refill, many factors have been taken into account. These considerations include fire resistance ability, safety hazards, structural comfort & stability, and the content of contaminants and harmful substances. The surface of our prototypes is smooth and flat