Suncenter  >  AI - Page Sitemap  >  DGT series oxygen gas booster pump
DGT series oxygen gas booster pump

DGT series oxygen gas booster pump

Moq
1 Set
Marque
SUNCENTER
Certificat
ISO/CE/SGS
garantie
13 Months
Emballage
By Plywood case
Port d'expédition
Shenzhen/Hongkong
Paiement
T/T,Western Union,Credit card.
Méthode de transaction
EXW,FOB,DDP,CIF,CFR
Lieu d'origine
Guangdong Province, China (Mainland)
Heure de livraison
Within 10-15 working days after received deposit
Prix
latest_price
latest_price_title
quantity_needed:
pieces
Courriel:
Product Comparison
booster pumps in Suncenter Fluid Control Equipment has the following advantages, compared with same kind of products in the market.
  • Suncenter-DGT series oxygen gas booster pump
    Suncenter-DGT series oxygen gas booster pump-1
Company Advantages
1. The gas booster system material of oxygen pumps makes it a automatic booster pump .
2. The product is proven to be energy efficient. It supports its operation by adopting energy conservation technology, consuming very little energy.
3. No defects can be found on this product, namely overall product failure or reduced usability of the product that prevents it from being placed on the market which can include open seams, holes or broken stitches.
4. Dongguan Suncenter Fluid Control Equipment Co., Ltd has broke through the conventional oxygen pumps production management.

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


DGT series oxygen gas booster pump-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


DGT series oxygen gas booster pump-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


DGT series oxygen gas booster pump-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. In the ever changing market, Suncenter always understands customers' needs and make change.
2. Suncenter places great emphasis on forward-looking technology applied in the manufacturing of oxygen pumps .
3. Dongguan Suncenter Fluid Control Equipment Co., Ltd provides professional service for every customer. Get price! Our core value is always treating customers with respect and faith. Ranging from all aspects of our business processes, we always adhere to integrity and business ethics. Get price! Our commitment is clear: we want to know it all. We like to have in-depth knowledge of the products we offer and take responsibility for the technical solutions we propose, from start to finish, maintaining full control over the delivery quality and deadlines.
The design & engineering team of Suncenter oxygen pumps applies state-of-the-art software and 3D mechanical CAD programming to finish the design from conception through completion. The product combines principles of simple operation with rugged construction
Suncenter oxygen pumps is processed with high-tech dyeing techniques. It will be dyed based on customers' requirements of different dyeing methods, mainly direct dyeing, mordant dyeing, overdye, or wet-on-wet dyeing. It has the capability of ultimate pressure, flow output horsepower
The quality of Suncenter automatic booster pump is guaranteed by a series of tests. It has gone through inspection on its seam force, tensile strength, fiber stiffness, fiber resilience, etc. It helps save costs and prevent contamination
The production of Suncenter gas booster system is well controlled by the computer. The computer exactly calculates the necessary amounts of raw materials, water, etc to reduce unnecessary waste. Its output pressure can be easily adjustable
Suncenter gas booster system is strictly inspected during production. It is checked on its appearance (porosity, scratches, dents or holes, paint runs, blisters, debris contamination). This product has the advantages of speed and efficiency
Product quality is guaranteed because of the rigorous quality control process that effectively eliminates defects. This product has the advantages of speed and efficiency
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting