Devenez l'expert mondial de premier ordre en matière de contrôle des fluides haute pression

Suncenter  >  AI - Page Sitemap  >  high quality pressure booster pump system type for safety valve calibration
high quality pressure booster pump system type for safety valve calibration

high quality pressure booster pump system type for safety valve calibration
  • high quality pressure booster pump system type for safety valve calibration
  • high quality pressure booster pump system type for safety valve calibration
  • high quality pressure booster pump system type for safety valve calibration
  • high quality pressure booster pump system type for safety valve calibration

high quality pressure booster pump system type for safety valve calibration

The production facilities used in Suncenter pressure booster pump are newly introduced with high efficiency. It will be processed under a welding machine, laser machine, automatic spray-painting machine, and surface polishing machine. The product has the advantage of shortcircuit protection
latest_price_title
quantity_needed:
pieces
Courriel:

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


high quality pressure booster pump system type for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


high quality pressure booster pump system type for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


high quality pressure booster pump system type for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Suncenter hydraulic pump test bench will be tested to guarantee its quality at the end of the stage. It will be tested by being dipped into or sprayed with different kinds of liquid such as acetic acid and alkaline liquid. The product is easy to plug and easy to use
Suncenter hydraulic pump test bench satisfies the general requirements for the safety of household and similar electrical appliances. It will be tested for safety issues including insulation, electric leakage, and short circuit. The product has been EMI/EMS certified
Suncenter hydraulic pump test bench is developed with a series of different critical performance properties taken into consideration, and some of these are Tensile, Tear Strength, Coating Adhesion, Weldability, Seam Strength, Flame Resistance, particularly UV and Weathering Resistance. The product has no risk of spontaneous combustion
Suncenter pressure booster pump has been optimized in the design. It is built with an energy-saving engine system, robust mechanical structure, and a more reasonable PLC system. Built-in advanced synchronous rectifier smart chip and EMI filter, the product effectively reduces electromagnetic interference
Suncenter hydraulic pump test bench is designed considering its operation processes. They include stress points, support points, yield points, wear resistance, toughness, friction force, etc. The strong housing helps protect against scratches, bumps, and drops
Our hydraulic pump test bench is made of cost-effective raw materials and automated mechanical equipment, with higher production efficiency and more obvious price advantages.
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting