Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  high quality nitrogen pumps gas for safety valve calibration
high quality nitrogen pumps gas for safety valve calibration

high quality nitrogen pumps gas for safety valve calibration
  • high quality nitrogen pumps gas for safety valve calibration
  • high quality nitrogen pumps gas for safety valve calibration
  • high quality nitrogen pumps gas for safety valve calibration
  • high quality nitrogen pumps gas for safety valve calibration

high quality nitrogen pumps gas for safety valve calibration

Suncenter gas booster system is strictly tested before shipped. Its fabric is tested for ingredients content and strength, and the color is tested for fastness under light and bleach. The product combines principles of simple operation with rugged construction
latest_price_title
quantity_needed:
pieces
Courriel:
Company Advantages
1. Suncenter gas booster system is strictly tested before shipped. Its fabric is tested for ingredients content and strength, and the color is tested for fastness under light and bleach. The product combines principles of simple operation with rugged construction
2. The product perfectly suits the application requirements of customers and now enjoys a larger market share. It can be tailored to meet the specific requirements of customers
3. The product offers a cushion effect. The softness and elasticity of the materials will significantly absorb the shock on the feet. It helps save costs and prevent contamination

Compressed Air Driven Gas Booster Pump- DGT Series


Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:


Applications for Air Driven Gas Boosters


SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.


Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.


As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.


SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.


high quality nitrogen pumps gas for safety valve calibration-1



DGT series gas booster pumps(Double acting, double stage, single air drive head ):


high quality nitrogen pumps gas for safety valve calibration-2
  • DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.  

  • DGT pumps are available with high quality seals, which provide significantly better service life  

  • All parts in contact with the gas are made of stainless steel. 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

DGT15

15:1

0.1

56

120

2-8 bar

15XPL

3/8/ 1/4

230(at PA of 8 bar )

DGT25

25:1

0.1

10

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT7/25

25:1

5

56

200

2-8 bar

25XPL

3/8/ 1/4

156(at PA of 8 bar )

DGT40

40:1

0.1

10

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT15/40

40:1

5

120

320

2-8 bar

40XPL

3/8/ 1/4

124(at PA of 8 bar )

DGT60

60:1

0.1

10

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT15/60

60:1

6

120

480

2-8 bar

60XPL

3/8/ 1/4

80(at PA of 15 bar )

DGT100

100:1

0.1

10

800

2-8 bar

100XPL

3/8/ 1/4

63(at PA of 8 bar )


2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):


high quality nitrogen pumps gas for safety valve calibration-3
  • 2DGT series gas booster pumps(Double acting, double stage,double air driven heads ) 


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (NPT thread)

Max. flow at driven air pressure of 6bar (L/min)

2DGT7/15

15:1

4

56

120

2bar-8 bar

15XPL

3/8 / 3/8

430(at PA of 10 bar )

2DGT7/25

25:1

5

56

200

2bar-8 bar

25XPL

3/8 / 3/8

300(at PA of 10 bar )

2DGT15/40

40:1

7

120

320

2bar-8 bar

40XPL

3/8 / 3/8

180(at PA of 10 bar )

2DGT15/60

60:1

7

120

480

2bar-8 bar

60XPL

3/8 / 3/8

120(at PA of 10 bar )



features

  •   Compressed Air driven - no electricity required (connect to normal air compressor)

  •   In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar  

  •   No airline lubricator required

  •   Hydrocarbon free - separation between air and gas sections

  •   Pressures to 80Mpa (11,600 psi)

  •   Wide range of models with different ratios

  •   Built-in-cooling on most models

  •   Easy to install, operate and maintain

  •   Best price / performance ratio

  •   No heat, flame or spark risk and explosion proof  

  •   Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant 

  •   Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO2/NO2/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


video





Company Features
1. With advanced laboratories, Suncenter can create superior nitrogen pumps with more confidence and win customers' attention.
2. We constantly invest in modernizing production facilities and office space, with a view to enhancing efficiency and further reducing our environmental impact.
For its material, we used nitrogen pumps that was typical for gas booster system because it is nitrogen pumps. It is able to quickly and effectively detect and respond to some types of input
gas booster system is made of high quality gas booster system with perfect performance such as gas booster system. The function of this product can be customized to meet the needs of liquids, granules, slurries, solids, and powder
Our gas booster system are constantly updated to follow the trend. This product has the advantage of chemical resistance
nitrogen pumps is more applicable to nitrogen pumps with its features of nitrogen pumps. Since it is maintenance-free, this product significantly helps save operation costs
gas booster system adopts gas booster system materials, generate features such as gas booster system. This product is easy to install and use
The quality of the product has been greatly assured by out stringent process quality control system. It is able to quickly and effectively detect and respond to some types of input
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting