Devenir l'expert en contrôle de fluide haute pression de première classe dans le monde

Suncenter  >  AI - Page Sitemap  >  easy to use nitrogen pumps pump for safety valve calibration
easy to use nitrogen pumps pump for safety valve calibration

easy to use nitrogen pumps pump for safety valve calibration
  • easy to use nitrogen pumps pump for safety valve calibration
  • easy to use nitrogen pumps pump for safety valve calibration
  • easy to use nitrogen pumps pump for safety valve calibration
  • easy to use nitrogen pumps pump for safety valve calibration

easy to use nitrogen pumps pump for safety valve calibration

Gas booster pressure test benchSuncenter - Air/Gas pressure test bench are compact and delicacy solution...
latest_price_title
quantity_needed:
pieces
Courriel:

Gas booster pressure test bench


Suncenter - Air/Gas pressure test bench are compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.


To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.


The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.


Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.


easy to use nitrogen pumps pump for safety valve calibration-1



The hottest selling- Model C frame type cabinet picture


easy to use nitrogen pumps pump for safety valve calibration-2
  • The standard gas booster pumps system including following parts:

  • Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

  • Stainless steel (carbon steel) material cabinet (Three models for choosing)

  • F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

  • Driven air switch (Pump starting switch), driven air pressure gauge

  • Gas inlet switch, Gas inlet pressure gauge

  • Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

  • And we could also customize it according to clients’ special requirement.


easy to use nitrogen pumps pump for safety valve calibration-3
  • DGS series air/gas pressure test bench with round chart recorder


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )


Technical specification for DGS-DGD series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas 

outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )


Technical specification for DGS-DGT series


Model

Pressure boost ratio

Min. gas
Inlet pressure
PA (bar)

Max.gas
Inlet pressure
PA (bar)

Max. gas
outlet pressure PB (bar)

 Driven air pressure  PL

Formula to
calculate gas outlet pressure PB

Connection:
Gas Inlet /
Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

2-8 bar

40XPL+ 6XPA

 1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

2-8 bar

60XPL+2.5XPA

 1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )


video





Suncenter nitrogen pumps is available in an attractive design and appealing finish. The product covers a wide range of functions
The Suncenter gas pressure testing provides reliable performance, and users won't have to worry about its quality. The product covers a wide range of functions
Suncenter nitrogen pumps is designed and crafted as we firmly follow international standards. The curing system of the product is of high performance
Suncenter nitrogen pumps is designed by a professional team who has many years of experiences in designing. The product is praised for its anti-chemical resistance
The materials of Suncenter gas pressure testing have remarkable advantages compared with the traditional ones. The product adopts a highly efficient feeding platform
The product is innoxious. All of the chemical agents used in it such as dyestuff, fixing agent, sterilizing agent, etc. It can run at a very high speed
Message du produit
Chat en ligne 编辑模式下无法使用
Laissez votre message inputting